OpenIPSL.Electrical.Solar.PowerFactory.General

General models for PowerFactory devices

Information

Extends from Modelica.Icons.Package (Icon for standard packages).

Package Content

Name Description
OpenIPSL.Electrical.Solar.PowerFactory.General.ElmGenstat ElmGenstat Static generator
OpenIPSL.Electrical.Solar.PowerFactory.General.ElmVac ElmVac Controllable voltage source
OpenIPSL.Electrical.Solar.PowerFactory.General.ElmPhi_pll ElmPhi_pll Phase-locked loop (PLL)
OpenIPSL.Electrical.Solar.PowerFactory.General.Picdro Picdro Pick-up drop-off implementation for protection functions

OpenIPSL.Electrical.Solar.PowerFactory.General.ElmGenstat OpenIPSL.Electrical.Solar.PowerFactory.General.ElmGenstat

Static generator

Information

Static generator implemented currently only as a current source.

Extends from OpenIPSL.Electrical.Essentials.pfComponent (Partial model containing all the parameters for entering power flow data).

Parameters

NameDescription
Power flow data
S_bSystem base power [VA]
V_bBase voltage of the bus [V]
fnSystem frequency [Hz]
P_0Initial active power [W]
Q_0Initial reactive power [var]
v_0Initial voltage magnitude [1]
angle_0Initial voltage angle [rad]
displayPFDisplay power flow:
Generator parameters
M_bMachine base power [VA]
pll_connectedEnable/disable use of PLL inputs
Parameter mask
enableS_bEnable S_b in parameter list
enableV_bEnable V_b in parameter list
enablefnEnable fn in parameter list
enableP_0Enable P_0 in parameter list
enableQ_0Enable Q_0 in parameter list
enablev_0Enable v_0 in parameter list
enableangle_0Enable angle_0 in parameter list
enabledisplayPFEnable displayPF in parameter list

Connectors

NameDescription
id_ref 
iq_ref 
p 
i 
v 
sinrefOptional PLL input for sine
cosrefOptional PLL input for cosine
P 
Q 

OpenIPSL.Electrical.Solar.PowerFactory.General.ElmVac OpenIPSL.Electrical.Solar.PowerFactory.General.ElmVac

Controllable voltage source

Information

Controllable voltage source with frequency and volage as inputs.

Extends from OpenIPSL.Electrical.Essentials.pfComponent (Partial model containing all the parameters for entering power flow data).

Parameters

NameDescription
Power flow data
S_bSystem base power [VA]
V_bBase voltage of the bus [V]
fnSystem frequency [Hz]
P_0Initial active power [W]
Q_0Initial reactive power [var]
v_0Initial voltage magnitude [1]
angle_0Initial voltage angle [rad]
displayPFDisplay power flow:
Parameter mask
enableS_bEnable S_b in parameter list
enableV_bEnable V_b in parameter list
enablefnEnable fn in parameter list
enableP_0Enable P_0 in parameter list
enableQ_0Enable Q_0 in parameter list
enablev_0Enable v_0 in parameter list
enableangle_0Enable angle_0 in parameter list
enabledisplayPFEnable displayPF in parameter list

Connectors

NameDescription
f0 
v 
p 

OpenIPSL.Electrical.Solar.PowerFactory.General.ElmPhi_pll OpenIPSL.Electrical.Solar.PowerFactory.General.ElmPhi_pll

Phase-locked loop (PLL)

Parameters

NameDescription
angle_0rad 
omega_0 
v_0 
PLLEnableEnable/disable PLL (PLL not implemented yet)

Connectors

NameDescription
p 
sinphi 
cosphi 

OpenIPSL.Electrical.Solar.PowerFactory.General.Picdro OpenIPSL.Electrical.Solar.PowerFactory.General.Picdro

Pick-up drop-off implementation for protection functions

Information

This function implements a logical pick-up-drop-off function commonly used when designingprotection schemes (e.g. fault detection, signal out-of-range, etc.).

Parameters

NameDescription
TpickPick-up time delay [s]
TdropDrop-off time delay [s]

Connectors

NameDescription
condition 
trip 
Automatically generated Thu Oct 6 17:41:44 2022.