Model for a Wind Machine based on a Duble-Fed Induction Generator (DFIG) with Active Power Control (Type 3)
Extends from Modelica.Icons.Package (Icon for standard packages).
Name | Description |
---|---|
WT3G1 | Wind Machine Model with DFIG and Ative Power Control done by a Converter (Type 3) |
WT3E1 | Electrical Control for Type 3 Wind Generator |
Wind Machine Model with DFIG and Ative Power Control done by a Converter (Type 3)
Extends from OpenIPSL.Electrical.Essentials.pfComponent (Partial model containing all the parameters for entering power flow data).
Name | Description |
---|---|
X_eq | Equivalent reactance for current injection [1] |
K_pll | PLL first integrator gain [1] |
K_ipll | PLL second integrator gain [1/s] |
P_llmax | PLL maximum limit [1] |
P_rated | Turbine rating, not used in the equation [W] |
Power flow data | |
S_b | System base power [VA] |
V_b | Base voltage of the bus [V] |
fn | System frequency [Hz] |
P_0 | Initial active power [W] |
Q_0 | Initial reactive power [var] |
v_0 | Initial voltage magnitude [1] |
angle_0 | Initial voltage angle [rad] |
displayPF | Display power flow: |
Zs | Equivalent impedance (ZSORCE) |
M_b | Machine base power [VA] |
Parameter mask | |
enableS_b | Enable S_b in parameter list |
enableV_b | Enable V_b in parameter list |
enablefn | Enable fn in parameter list |
enableP_0 | Enable P_0 in parameter list |
enableQ_0 | Enable Q_0 in parameter list |
enablev_0 | Enable v_0 in parameter list |
enableangle_0 | Enable angle_0 in parameter list |
enabledisplayPF | Enable displayPF in parameter list |
Name | Description |
---|---|
p | |
Iy | |
Ix | |
Iterm | |
Eqcmd | |
Ipcmd | |
delta | |
V | |
P | On machine base |
Q | |
ipcmd0 | |
eqcmd0 |
Electrical Control for Type 3 Wind Generator
Name | Description |
---|---|
VARFLG | 0 constant Q; 1 Reactive control; -1 Constant PF control |
VLRFLG | 0 Bypass V control; 1 WT3G1 Eqcmd limits;2 WT3G2 Eqcmd limits |
Tfv | Filter time constant in voltage regulator [s] |
Kpv | Proportional gain in voltage regulator [1] |
KIV | Integrator gain in voltage regulator [1/s] |
Xc | Line drop compensation reactance [1] |
TFP | Filter time constant in torque regulator [s] |
Kpp | Proportional gain in torque regulator [1] |
KIP | Integrator gain in torque regulator [1/s] |
PMX | Max limit in torque regulator [1] |
PMN | Min limit in torque regulator [1] |
QMX | Max limit in voltage regulator [1] |
QMN | Min limit in voltage regulator [1] |
IPMAX | Max active current limit [1] |
TRV | Voltage sensor time constant [s] |
RPMX | Max power order derivative [1] |
RPMN | Min power order derivative [1] |
T_Power | Power filter time constant [s] |
Kqi | Mvar/Voltage gain [1] |
VMINCL | Min voltage limit [1] |
VMAXCL | Max voltage limit [1] |
Kqv | Voltage/Mvar gain [1] |
XIQmin | [1] |
XIQmax | [1] |
Tv | Lag time constant in WindVar controller [s] |
Tp | Pelec filter in fast PF controller [s] |
Fn | A portion of online wind turbines |
wPmin | Shaft speed at Pmin [1] |
wP20 | Shaft speed at 20% rated power [1] |
wP40 | Shaft speed at 40% rated power [1] |
wP60 | Shaft speed at 60% rated power [1] |
Pmin | Minimum power for operating at P100 speed [1] |
wP100 | Shaft speed at 100% rated power [1] |
Vref | Remote bus ref voltage [1] |
v0 | [1] |
p0 | [1] |
q0 | [1] |
Name | Description |
---|---|
PELEC | |
VTERM | |
WIPCMD | |
Qelec | |
WEQCMD | |
WPCMND | |
ITERM | magnitude of terminal current |
WEQCMD0 | |
WIPCMD0 |