OpenIPSL.Examples.DAEMode.N44_Base_Case_Systems

Test systems related to the N44 Base Case

Information

This package contains variants of Nordic 44 test system for testing performance of numerical solvers.

Extends from Modelica.Icons.ExamplesPackage (Icon for packages containing runnable examples).

Package Content

Name Description
OpenIPSL.Examples.DAEMode.N44_Base_Case_Systems.Nordic44_Base_Case_StateEvents Nordic44_Base_Case_StateEvents Modified version of the original Nordic 44 model, base class for Bus 5603 bus fault experiment
OpenIPSL.Examples.DAEMode.N44_Base_Case_Systems.Nordic44_Base_Case_StateEvents2 Nordic44_Base_Case_StateEvents2 Modified version of the original Nordic 44 model, used to simulate with DAE mode
OpenIPSL.Examples.DAEMode.N44_Base_Case_Systems.Nordic44_Base_Case_StateEvents3 Nordic44_Base_Case_StateEvents3 Bus 5603 bus fault experiments. The start values were given by simulating Nordic44_Base_Case_StateEvents2 from t = 0s to t = 60s. These start values have been stored in this model
OpenIPSL.Examples.DAEMode.N44_Base_Case_Systems.Generators Generators Group of generator models for N44 system simulations with events

OpenIPSL.Examples.DAEMode.N44_Base_Case_Systems.Nordic44_Base_Case_StateEvents OpenIPSL.Examples.DAEMode.N44_Base_Case_Systems.Nordic44_Base_Case_StateEvents

Modified version of the original Nordic 44 model, base class for Bus 5603 bus fault experiment

Information

Simulation of the Nordic 44 test system, in its base case scenario, with a fault occurring at bus , triggering several events. Try simulating the system with an fixed time-step solver, without a DAE mode, and with a time-step of 10ms.

Simulate the system for 5 seconds. Variables of interest are:

Compare with the results obtained in Nordic44_Base_Case_Bus_StateEvents2. Note that this test system takes a lot of time to simulate.

Extends from Modelica.Icons.Example (Icon for runnable examples).

OpenIPSL.Examples.DAEMode.N44_Base_Case_Systems.Nordic44_Base_Case_StateEvents2 OpenIPSL.Examples.DAEMode.N44_Base_Case_Systems.Nordic44_Base_Case_StateEvents2

Modified version of the original Nordic 44 model, used to simulate with DAE mode

Information

Simulation of the Nordic 44 test system, in its base case scenario, with a fault occurring at bus , triggering several events. Try simulating the system in DAE mode when in Dymola.

Simulate the system for 5 seconds. Variables of interest are:

Simulate Compare with the results obtained in Nordic44_Base_Case_Bus_StateEvents. Note that it takes significantly less time to simulate this system.

Extends from Modelica.Icons.Example (Icon for runnable examples).

OpenIPSL.Examples.DAEMode.N44_Base_Case_Systems.Nordic44_Base_Case_StateEvents3 OpenIPSL.Examples.DAEMode.N44_Base_Case_Systems.Nordic44_Base_Case_StateEvents3

Bus 5603 bus fault experiments. The start values were given by simulating Nordic44_Base_Case_StateEvents2 from t = 0s to t = 60s. These start values have been stored in this model

Information

Extends from OpenIPSL.Examples.DAEMode.N44_Base_Case_Systems.Nordic44_Base_Case_StateEvents (Modified version of the original Nordic 44 model, base class for Bus 5603 bus fault experiment).

Automatically generated Thu Oct 6 17:41:43 2022.