Set of generation unit models used in IEEE (WSCC) 9-bus system
This package contains three generation unit models, composed of machine and exciter models, that are used in the IEEE (WSCC) 9-bus system. These models are:
The generation units also allow for a disturbance in the excitation system reference to be introduced.
Name | Description |
---|---|
Gen1 | 18kV/100MVA generation unit connected to bus 2 |
Gen2 | 13.8kV/100MVA generation unit connected to bus 3 |
Gen3 | 16.5kV/100MVA generation unit connected to bus 1 |
18kV/100MVA generation unit connected to bus 2
18kV/100MVA Generation unit, identified as number 1, connected to bus 2, and composed of the following component models:
Note that the model allows for a disturbance to be introduced in the voltage reference value for the excitation system.
Extends from OpenIPSL.Electrical.Essentials.pfComponent (Partial model containing all the parameters for entering power flow data).
Name | Description |
---|---|
vf0 | |
vref0 | |
Power flow data | |
S_b | System base power [VA] |
V_b | Base voltage of the bus [V] |
fn | System frequency [Hz] |
P_0 | Initial active power [W] |
Q_0 | Initial reactive power [var] |
v_0 | Initial voltage magnitude [1] |
angle_0 | Initial voltage angle [rad] |
displayPF | Display power flow: |
AVR Disturbance | |
height_1 | |
tstart_1 | |
refdisturb_1 | |
Parameter mask | |
enableS_b | Enable S_b in parameter list |
enableV_b | Enable V_b in parameter list |
enablefn | Enable fn in parameter list |
enableP_0 | Enable P_0 in parameter list |
enableQ_0 | Enable Q_0 in parameter list |
enablev_0 | Enable v_0 in parameter list |
enableangle_0 | Enable angle_0 in parameter list |
enabledisplayPF | Enable displayPF in parameter list |
Name | Description |
---|---|
pwPin |
13.8kV/100MVA generation unit connected to bus 3
13.8kV/100MVA Generation unit, identified as number 2, connected to bus 3, and composed of the following component models:
Note that the model allows for a disturbance to be introduced in the voltage reference value for the excitation system.
Extends from OpenIPSL.Electrical.Essentials.pfComponent (Partial model containing all the parameters for entering power flow data).
Name | Description |
---|---|
vf0 | |
vref0 | |
Power flow data | |
S_b | System base power [VA] |
V_b | Base voltage of the bus [V] |
fn | System frequency [Hz] |
P_0 | Initial active power [W] |
Q_0 | Initial reactive power [var] |
v_0 | Initial voltage magnitude [1] |
angle_0 | Initial voltage angle [rad] |
displayPF | Display power flow: |
AVR Disturbance | |
height_2 | |
tstart_2 | |
refdisturb_2 | |
Parameter mask | |
enableS_b | Enable S_b in parameter list |
enableV_b | Enable V_b in parameter list |
enablefn | Enable fn in parameter list |
enableP_0 | Enable P_0 in parameter list |
enableQ_0 | Enable Q_0 in parameter list |
enablev_0 | Enable v_0 in parameter list |
enableangle_0 | Enable angle_0 in parameter list |
enabledisplayPF | Enable displayPF in parameter list |
Name | Description |
---|---|
pwPin |
16.5kV/100MVA generation unit connected to bus 1
16.5kV/100MVA Generation unit, identified as number 3, connected to bus 1, and composed of the following component models:
Note that the model allows for a disturbance to be introduced in the voltage reference value for the excitation system.
Extends from OpenIPSL.Electrical.Essentials.pfComponent (Partial model containing all the parameters for entering power flow data).
Name | Description |
---|---|
vf0 | |
vref0 | |
Power flow data | |
S_b | System base power [VA] |
V_b | Base voltage of the bus [V] |
fn | System frequency [Hz] |
P_0 | Initial active power [W] |
Q_0 | Initial reactive power [var] |
v_0 | Initial voltage magnitude [1] |
angle_0 | Initial voltage angle [rad] |
displayPF | Display power flow: |
AVR Disturbance | |
height_3 | |
tstart_3 | |
refdisturb_3 | |
Parameter mask | |
enableS_b | Enable S_b in parameter list |
enableV_b | Enable V_b in parameter list |
enablefn | Enable fn in parameter list |
enableP_0 | Enable P_0 in parameter list |
enableQ_0 | Enable Q_0 in parameter list |
enablev_0 | Enable v_0 in parameter list |
enableangle_0 | Enable angle_0 in parameter list |
enabledisplayPF | Enable displayPF in parameter list |
Name | Description |
---|---|
pwPin |