Machine models from PSAT
Extends from Modelica.Icons.Package (Icon for standard packages).
| Name | Description |
|---|---|
| Second Order Synchronous Machine with Inputs and Outputs | |
| Third Order Synchronous Machine with Inputs and Outputs | |
| Fourth Order Synchronous Machine with Inputs and Outputs | |
| 5th order machine model, type 1 | |
| 5th order machine model, type 2 | |
| 6th order machine model | |
| Induction Machine - Order I | |
| Induction Machine - Order III | |
| Induction Machine - Order V | |
| Base classes for PSAT machines |
OpenIPSL.Electrical.Machines.PSAT.Order2Second Order Synchronous Machine with Inputs and Outputs
Extends from BaseClasses.baseMachine (Base machine for PSAT models).
| Name | Description |
|---|---|
| Power flow data | |
| S_b | System base power [V.A] |
| V_b | Base voltage of the bus [V] |
| fn | System frequency [Hz] |
| P_0 | Initial active power [W] |
| Q_0 | Initial reactive power [var] |
| v_0 | Initial voltage magnitude [1] |
| angle_0 | Initial voltage angle [rad] |
| displayPF | Display power flow: |
| Machine parameters | |
| Sn | Power rating [V.A] |
| Vn | Voltage rating [V] |
| ra | Armature resistance [1] |
| x1d | d-axis transient reactance [1] |
| M | Mechanical starting time, 2H [Ws/VA] [s] |
| D | Damping coefficient |
| Initialization | |
| w | Rotor speed [pu] |
| Name | Description |
|---|---|
| p | |
| delta | Rotor angle [rad] |
| v | Generator terminal voltage [pu] |
| P | Active power [pu] |
| Q | Reactive power [pu] |
| vf0 | Initial field voltage [pu] |
| pm0 | Initial mechanical power [pu] |
| pm | Mechanical power [pu] |
| Initialization | |
| w | Rotor speed [pu] |
OpenIPSL.Electrical.Machines.PSAT.Order3Third Order Synchronous Machine with Inputs and Outputs
Extends from BaseClasses.baseMachine (Base machine for PSAT models).
| Name | Description |
|---|---|
| Power flow data | |
| S_b | System base power [V.A] |
| V_b | Base voltage of the bus [V] |
| fn | System frequency [Hz] |
| P_0 | Initial active power [W] |
| Q_0 | Initial reactive power [var] |
| v_0 | Initial voltage magnitude [1] |
| angle_0 | Initial voltage angle [rad] |
| displayPF | Display power flow: |
| Machine parameters | |
| Sn | Power rating [V.A] |
| Vn | Voltage rating [V] |
| ra | Armature resistance [1] |
| x1d | d-axis transient reactance [1] |
| M | Mechanical starting time, 2H [Ws/VA] [s] |
| D | Damping coefficient |
| xd | d-axis synchronous reactance [1] |
| T1d0 | d-axis open circuit transient time constant [s] |
| xq | q-axis synchronous reactance [1] |
| Initialization | |
| w | Rotor speed [pu] |
| Name | Description |
|---|---|
| p | |
| delta | Rotor angle [rad] |
| v | Generator terminal voltage [pu] |
| P | Active power [pu] |
| Q | Reactive power [pu] |
| vf0 | Initial field voltage [pu] |
| pm0 | Initial mechanical power [pu] |
| pm | Mechanical power [pu] |
| Initialization | |
| w | Rotor speed [pu] |
OpenIPSL.Electrical.Machines.PSAT.Order4Fourth Order Synchronous Machine with Inputs and Outputs
Extends from BaseClasses.baseMachine (Base machine for PSAT models).
| Name | Description |
|---|---|
| Power flow data | |
| S_b | System base power [V.A] |
| V_b | Base voltage of the bus [V] |
| fn | System frequency [Hz] |
| P_0 | Initial active power [W] |
| Q_0 | Initial reactive power [var] |
| v_0 | Initial voltage magnitude [1] |
| angle_0 | Initial voltage angle [rad] |
| displayPF | Display power flow: |
| Machine parameters | |
| Sn | Power rating [V.A] |
| Vn | Voltage rating [V] |
| ra | Armature resistance [1] |
| x1d | d-axis transient reactance [1] |
| M | Mechanical starting time, 2H [Ws/VA] [s] |
| D | Damping coefficient |
| xd | d-axis synchronous reactance [1] |
| xq | q-axis synchronous reactance [1] |
| x1q | q-axis transient reactance [1] |
| T1d0 | d-axis open circuit transient time constant [s] |
| T1q0 | q-axis open circuit transient time constant [s] |
| Initialization | |
| w | Rotor speed [pu] |
| Name | Description |
|---|---|
| p | |
| delta | Rotor angle [rad] |
| v | Generator terminal voltage [pu] |
| P | Active power [pu] |
| Q | Reactive power [pu] |
| vf0 | Initial field voltage [pu] |
| pm0 | Initial mechanical power [pu] |
| pm | Mechanical power [pu] |
| Initialization | |
| w | Rotor speed [pu] |
OpenIPSL.Electrical.Machines.PSAT.Order5_Type15th order machine model, type 1
Extends from BaseClasses.baseMachine (Base machine for PSAT models).
| Name | Description |
|---|---|
| Power flow data | |
| S_b | System base power [V.A] |
| V_b | Base voltage of the bus [V] |
| fn | System frequency [Hz] |
| P_0 | Initial active power [W] |
| Q_0 | Initial reactive power [var] |
| v_0 | Initial voltage magnitude [1] |
| angle_0 | Initial voltage angle [rad] |
| displayPF | Display power flow: |
| Machine parameters | |
| Sn | Power rating [V.A] |
| Vn | Voltage rating [V] |
| ra | Armature resistance [1] |
| x1d | d-axis transient reactance [1] |
| M | Mechanical starting time, 2H [Ws/VA] [s] |
| D | Damping coefficient |
| xd | d-axis synchronous reactance [1] |
| xq | q-axis synchronous reactance [1] |
| x1q | q-axis transient reactance [1] |
| T1d0 | d-axis open circuit transient time constant [s] |
| T1q0 | q-axis open circuit transient time constant [s] |
| T2q0 | q-axis open circuit sub-transient time constant [s] |
| Initialization | |
| w | Rotor speed [pu] |
| Name | Description |
|---|---|
| p | |
| delta | Rotor angle [rad] |
| v | Generator terminal voltage [pu] |
| P | Active power [pu] |
| Q | Reactive power [pu] |
| vf0 | Initial field voltage [pu] |
| pm0 | Initial mechanical power [pu] |
| pm | Mechanical power [pu] |
| Initialization | |
| w | Rotor speed [pu] |
OpenIPSL.Electrical.Machines.PSAT.Order5_Type25th order machine model, type 2
Extends from BaseClasses.baseMachine (Base machine for PSAT models).
| Name | Description |
|---|---|
| Power flow data | |
| S_b | System base power [V.A] |
| V_b | Base voltage of the bus [V] |
| fn | System frequency [Hz] |
| P_0 | Initial active power [W] |
| Q_0 | Initial reactive power [var] |
| v_0 | Initial voltage magnitude [1] |
| angle_0 | Initial voltage angle [rad] |
| displayPF | Display power flow: |
| Machine parameters | |
| Sn | Power rating [V.A] |
| Vn | Voltage rating [V] |
| ra | Armature resistance [1] |
| x1d | d-axis transient reactance [1] |
| M | Mechanical starting time, 2H [Ws/VA] [s] |
| D | Damping coefficient |
| xd | d-axis synchronous reactance [1] |
| xq | q-axis synchronous reactance [1] |
| x2d | d-axis sub-transient reactance [1] |
| x2q | q-axis sub-transient reactance [1] |
| T1d0 | d-axis open circuit transient time constant [s] |
| T2d0 | d-axis open circuit sub-transient time constant [s] |
| T2q0 | q-axis open circuit sub-transient time constant [s] |
| Taa | d-axis additional leakage time constant [s] |
| Initialization | |
| w | Rotor speed [pu] |
| Name | Description |
|---|---|
| p | |
| delta | Rotor angle [rad] |
| v | Generator terminal voltage [pu] |
| P | Active power [pu] |
| Q | Reactive power [pu] |
| vf0 | Initial field voltage [pu] |
| pm0 | Initial mechanical power [pu] |
| pm | Mechanical power [pu] |
| Initialization | |
| w | Rotor speed [pu] |
OpenIPSL.Electrical.Machines.PSAT.Order66th order machine model
Extends from BaseClasses.baseMachine (Base machine for PSAT models).
| Name | Description |
|---|---|
| Power flow data | |
| S_b | System base power [V.A] |
| V_b | Base voltage of the bus [V] |
| fn | System frequency [Hz] |
| P_0 | Initial active power [W] |
| Q_0 | Initial reactive power [var] |
| v_0 | Initial voltage magnitude [1] |
| angle_0 | Initial voltage angle [rad] |
| displayPF | Display power flow: |
| Machine parameters | |
| Sn | Power rating [V.A] |
| Vn | Voltage rating [V] |
| ra | Armature resistance [1] |
| x1d | d-axis transient reactance [1] |
| M | Mechanical starting time, 2H [Ws/VA] [s] |
| D | Damping coefficient |
| xd | d-axis synchronous reactance [1] |
| xq | q-axis synchronous reactance [1] |
| x1q | q-axis transient reactance [1] |
| x2d | d-axis sub-transient reactance [1] |
| x2q | q-axis sub-transient reactance [1] |
| T1d0 | d-axis open circuit transient time constant [s] |
| T1q0 | q-axis open circuit transient time constant [s] |
| T2d0 | d-axis open circuit sub-transient time constant [s] |
| T2q0 | q-axis open circuit sub-transient time constant [s] |
| Taa | d-axis additional leakage time constant [s] |
| Initialization | |
| w | Rotor speed [pu] |
| Name | Description |
|---|---|
| p | |
| delta | Rotor angle [rad] |
| v | Generator terminal voltage [pu] |
| P | Active power [pu] |
| Q | Reactive power [pu] |
| vf0 | Initial field voltage [pu] |
| pm0 | Initial mechanical power [pu] |
| pm | Mechanical power [pu] |
| Initialization | |
| w | Rotor speed [pu] |
OpenIPSL.Electrical.Machines.PSAT.MotorTypeIInduction Machine - Order I
Extends from OpenIPSL.Electrical.Essentials.pfComponent (Partial model containing all the parameters for entering power flow data).
| Name | Description |
|---|---|
| Power flow data | |
| S_b | System base power [V.A] |
| V_b | Base voltage of the bus [V] |
| fn | System frequency [Hz] |
| P_0 | Initial active power [W] |
| Q_0 | Initial reactive power [var] |
| v_0 | Initial voltage magnitude [1] |
| angle_0 | Initial voltage angle [rad] |
| displayPF | Display power flow: |
| Machine parameters | |
| Sup | Start-up control |
| Rs | Stator resistance [1] |
| Xs | Stator reactance [1] |
| Rr1 | 1st cage rotor resistance [1] |
| Xr1 | 1st cage rotor reactance [1] |
| Xm | Magnetizing reactance [1] |
| Hm | Inertia constant [Ws/VA] [s] |
| a | 1st coefficient of tau_m(w) [1] |
| b | 2nd coefficient of tau_m(w) [1] |
| c | 3rd coefficient of tau_m(w) [1] |
| tup | Start up time [s] |
| Parameter mask | |
| enableS_b | Enable S_b in parameter list |
| enableV_b | Enable V_b in parameter list |
| enablefn | Enable fn in parameter list |
| enableP_0 | Enable P_0 in parameter list |
| enableQ_0 | Enable Q_0 in parameter list |
| enablev_0 | Enable v_0 in parameter list |
| enableangle_0 | Enable angle_0 in parameter list |
| enabledisplayPF | Enable displayPF in parameter list |
| Name | Description |
|---|---|
| p |
OpenIPSL.Electrical.Machines.PSAT.MotorTypeIIIInduction Machine - Order III
Extends from OpenIPSL.Electrical.Essentials.pfComponent (Partial model containing all the parameters for entering power flow data).
| Name | Description |
|---|---|
| Power flow data | |
| S_b | System base power [V.A] |
| V_b | Base voltage of the bus [V] |
| fn | System frequency [Hz] |
| P_0 | Initial active power [W] |
| Q_0 | Initial reactive power [var] |
| v_0 | Initial voltage magnitude [1] |
| angle_0 | Initial voltage angle [rad] |
| displayPF | Display power flow: |
| Machine parameters | |
| Sup | Start up control |
| Rs | Stator resistance [1] |
| Xs | Stator reactance [1] |
| Rr1 | 1st cage rotor resistance [1] |
| Xr1 | 1st cage rotor reactance [1] |
| Xm | Magnetizing reactance [1] |
| Hm | Inertia constant [s] |
| a | 1st coefficient of tau_m(w) [1] |
| b | 2nd coefficient of tau_m(w) [1] |
| c | 3rd coefficient of tau_m(w) [1] |
| tup | Start up time [s] |
| Parameter mask | |
| enableS_b | Enable S_b in parameter list |
| enableV_b | Enable V_b in parameter list |
| enablefn | Enable fn in parameter list |
| enableP_0 | Enable P_0 in parameter list |
| enableQ_0 | Enable Q_0 in parameter list |
| enablev_0 | Enable v_0 in parameter list |
| enableangle_0 | Enable angle_0 in parameter list |
| enabledisplayPF | Enable displayPF in parameter list |
| Name | Description |
|---|---|
| p |
OpenIPSL.Electrical.Machines.PSAT.MotorTypeVInduction Machine - Order V
Extends from OpenIPSL.Electrical.Essentials.pfComponent (Partial model containing all the parameters for entering power flow data).
| Name | Description |
|---|---|
| Power flow data | |
| S_b | System base power [V.A] |
| V_b | Base voltage of the bus [V] |
| fn | System frequency [Hz] |
| P_0 | Initial active power [W] |
| Q_0 | Initial reactive power [var] |
| v_0 | Initial voltage magnitude [1] |
| angle_0 | Initial voltage angle [rad] |
| displayPF | Display power flow: |
| Machine parameters | |
| Sup | Start up control |
| Rs | Stator resistance [1] |
| Xs | Stator reactance [1] |
| Rr1 | 1st cage rotor resistance [1] |
| Xr1 | 1st cage rotor reactance [1] |
| Rr2 | 2nd cage rotor resistance [1] |
| Xr2 | 2nd cage rotor reactance [1] |
| Xm | Magnetizing reactance [1] |
| Hm | Inertia constant [s] |
| a | 1st coefficient of tau_m(w) [1] |
| b | 2nd coefficient of tau_m(w) [1] |
| c | 3rd coefficient of tau_m(w) [1] |
| tup | Start up time [s] |
| Parameter mask | |
| enableS_b | Enable S_b in parameter list |
| enableV_b | Enable V_b in parameter list |
| enablefn | Enable fn in parameter list |
| enableP_0 | Enable P_0 in parameter list |
| enableQ_0 | Enable Q_0 in parameter list |
| enablev_0 | Enable v_0 in parameter list |
| enableangle_0 | Enable angle_0 in parameter list |
| enabledisplayPF | Enable displayPF in parameter list |
| Name | Description |
|---|---|
| p |