General models for PowerFactory devices
Extends from Modelica.Icons.Package (Icon for standard packages).
Name | Description |
---|---|
ElmGenstat | Static generator |
ElmVac | Controllable voltage source |
ElmPhi_pll | Phase-locked loop (PLL) |
Picdro | Pick-up drop-off implementation for protection functions |
Static generator
Static generator implemented currently only as a current source.
Extends from OpenIPSL.Electrical.Essentials.pfComponent (Partial model containing all the parameters for entering power flow data).
Name | Description |
---|---|
Power flow data | |
S_b | System base power [V.A] |
V_b | Base voltage of the bus [V] |
fn | System frequency [Hz] |
P_0 | Initial active power [W] |
Q_0 | Initial reactive power [var] |
v_0 | Initial voltage magnitude [1] |
angle_0 | Initial voltage angle [rad] |
displayPF | Display power flow: |
Generator parameters | |
M_b | Machine base power [V.A] |
pll_connected | Enable/disable use of PLL inputs |
Parameter mask | |
enableS_b | Enable S_b in parameter list |
enableV_b | Enable V_b in parameter list |
enablefn | Enable fn in parameter list |
enableP_0 | Enable P_0 in parameter list |
enableQ_0 | Enable Q_0 in parameter list |
enablev_0 | Enable v_0 in parameter list |
enableangle_0 | Enable angle_0 in parameter list |
enabledisplayPF | Enable displayPF in parameter list |
Name | Description |
---|---|
id_ref | |
iq_ref | |
p | |
i | |
v | |
sinref | Optional PLL input for sine |
cosref | Optional PLL input for cosine |
P | |
Q |
Controllable voltage source
Controllable voltage source with frequency and volage as inputs.
Extends from OpenIPSL.Electrical.Essentials.pfComponent (Partial model containing all the parameters for entering power flow data).
Name | Description |
---|---|
Power flow data | |
S_b | System base power [V.A] |
V_b | Base voltage of the bus [V] |
fn | System frequency [Hz] |
P_0 | Initial active power [W] |
Q_0 | Initial reactive power [var] |
v_0 | Initial voltage magnitude [1] |
angle_0 | Initial voltage angle [rad] |
displayPF | Display power flow: |
Parameter mask | |
enableS_b | Enable S_b in parameter list |
enableV_b | Enable V_b in parameter list |
enablefn | Enable fn in parameter list |
enableP_0 | Enable P_0 in parameter list |
enableQ_0 | Enable Q_0 in parameter list |
enablev_0 | Enable v_0 in parameter list |
enableangle_0 | Enable angle_0 in parameter list |
enabledisplayPF | Enable displayPF in parameter list |
Name | Description |
---|---|
f0 | |
v | |
p |
Phase-locked loop (PLL)
Name | Description |
---|---|
angle_0rad | |
omega_0 | |
v_0 | |
PLLEnable | Enable/disable PLL (PLL not implemented yet) |
Name | Description |
---|---|
p | |
sinphi | |
cosphi |
Pick-up drop-off implementation for protection functions
This function implements a logical pick-up-drop-off function commonly used when designingprotection schemes (e.g. fault detection, signal out-of-range, etc.).
Name | Description |
---|---|
Tpick | Pick-up time delay [s] |
Tdrop | Drop-off time delay [s] |
Name | Description |
---|---|
condition | |
trip |