Model for a Wind Machine based on a Duble-Fed Induction Generator (DFIG) with Active Power Control (Type 3)
Extends from Modelica.Icons.Package (Icon for standard packages).
| Name | Description |
|---|---|
| Wind Machine Model with DFIG and Ative Power Control done by a Converter (Type 3) | |
| Electrical Control for Type 3 Wind Generator |
OpenIPSL.Electrical.Wind.PSSE.WT3G.WT3G1Wind Machine Model with DFIG and Ative Power Control done by a Converter (Type 3)
Extends from OpenIPSL.Electrical.Essentials.pfComponent (Partial model containing all the parameters for entering power flow data).
| Name | Description |
|---|---|
| X_eq | Equivalent reactance for current injection [1] |
| K_pll | PLL first integrator gain [1] |
| K_ipll | PLL second integrator gain [1/s] |
| P_llmax | PLL maximum limit [1] |
| P_rated | Turbine rating, not used in the equation [W] |
| Power flow data | |
| S_b | System base power [V.A] |
| V_b | Base voltage of the bus [V] |
| fn | System frequency [Hz] |
| P_0 | Initial active power [W] |
| Q_0 | Initial reactive power [var] |
| v_0 | Initial voltage magnitude [1] |
| angle_0 | Initial voltage angle [rad] |
| displayPF | Display power flow: |
| Zs | Equivalent impedance (ZSORCE) |
| M_b | Machine base power [V.A] |
| Parameter mask | |
| enableS_b | Enable S_b in parameter list |
| enableV_b | Enable V_b in parameter list |
| enablefn | Enable fn in parameter list |
| enableP_0 | Enable P_0 in parameter list |
| enableQ_0 | Enable Q_0 in parameter list |
| enablev_0 | Enable v_0 in parameter list |
| enableangle_0 | Enable angle_0 in parameter list |
| enabledisplayPF | Enable displayPF in parameter list |
| Name | Description |
|---|---|
| p | |
| Iy | |
| Ix | |
| Iterm | |
| Eqcmd | |
| Ipcmd | |
| delta | |
| V | |
| P | On machine base |
| Q | |
| ipcmd0 | |
| eqcmd0 |
OpenIPSL.Electrical.Wind.PSSE.WT3G.WT3E1Electrical Control for Type 3 Wind Generator
| Name | Description |
|---|---|
| VARFLG | 0 constant Q; 1 Reactive control; -1 Constant PF control |
| VLRFLG | 0 Bypass V control; 1 WT3G1 Eqcmd limits;2 WT3G2 Eqcmd limits |
| Tfv | Filter time constant in voltage regulator [s] |
| Kpv | Proportional gain in voltage regulator [1] |
| KIV | Integrator gain in voltage regulator [1/s] |
| Xc | Line drop compensation reactance [1] |
| TFP | Filter time constant in torque regulator [s] |
| Kpp | Proportional gain in torque regulator [1] |
| KIP | Integrator gain in torque regulator [1/s] |
| PMX | Max limit in torque regulator [1] |
| PMN | Min limit in torque regulator [1] |
| QMX | Max limit in voltage regulator [1] |
| QMN | Min limit in voltage regulator [1] |
| IPMAX | Max active current limit [1] |
| TRV | Voltage sensor time constant [s] |
| RPMX | Max power order derivative [1] |
| RPMN | Min power order derivative [1] |
| T_Power | Power filter time constant [s] |
| Kqi | Mvar/Voltage gain [1] |
| VMINCL | Min voltage limit [1] |
| VMAXCL | Max voltage limit [1] |
| Kqv | Voltage/Mvar gain [1] |
| XIQmin | [1] |
| XIQmax | [1] |
| Tv | Lag time constant in WindVar controller [s] |
| Tp | Pelec filter in fast PF controller [s] |
| Fn | A portion of online wind turbines |
| wPmin | Shaft speed at Pmin [1] |
| wP20 | Shaft speed at 20% rated power [1] |
| wP40 | Shaft speed at 40% rated power [1] |
| wP60 | Shaft speed at 60% rated power [1] |
| Pmin | Minimum power for operating at P100 speed [1] |
| wP100 | Shaft speed at 100% rated power [1] |
| Vref | Remote bus ref voltage [1] |
| v0 | [1] |
| p0 | [1] |
| q0 | [1] |
| Name | Description |
|---|---|
| PELEC | |
| VTERM | |
| WIPCMD | |
| Qelec | |
| WEQCMD | |
| WPCMND | |
| ITERM | magnitude of terminal current |
| WEQCMD0 | |
| WIPCMD0 |