OpenIPSL.Examples.N44.Base_Case

Library of modified Nordic 44 model

Information

This repository contains models for the modified Nordic 44 system.

Extends from Modelica.Icons.ExamplesPackage (Icon for packages containing runnable examples).

Package Content

Name Description
OpenIPSL.Examples.N44.Base_Case.Nordic44_Base_Case Nordic44_Base_Case Modified version of the original Nordic 44 model
OpenIPSL.Examples.N44.Base_Case.Data Data Modelica records containing power flow results
OpenIPSL.Examples.N44.Base_Case.Generators Generators Package of generator groups for the Nordic 44 model

OpenIPSL.Examples.N44.Base_Case.Nordic44_Base_Case OpenIPSL.Examples.N44.Base_Case.Nordic44_Base_Case

Modified version of the original Nordic 44 model

Information

This example system represents the Nordic 44 test system, represented differently from the original case, but undergoing the same line opening event.

Simulate the system for 10 seconds. If you are using Dymola, use the DAE mode. Variables of interest are:

Compare these results with the ones obtained in the Nordic44_Base_Case.

Changes compared to the original case (Real data period: April, May, June and July):

Trafo Buses (Line Reactance)

Old Rate A

Old Rate B

Old Rate C

New Rate A

New Rate B

New Rate C

3100-3115 (Xline=0.4)

1100

1300

1400

2000

2500

3000

3100-3249 (Xline=0.43)

1100

1300

1400

2000

2500

3000

3200-8500 (Xline=0.17)

1100

1300

1400

1900

2200

2600

3249-7100 (Xline=0.075)

1300

1500

1700

1900

2200

2600

3300-8500 (Xline=0.23,027)

1100

1300

1400

1900

2200

2600

5300-6100 (Xline=0.22)

800

900

950

1900

2200

2600

5400-5500 (Xline=0.094)

400

550

650

1900

2200

2600

5402-6001 (Xline=0.01)

1500

1700

1900

2100

2500

3000

6000-6100 (Xline=0.42)

800

900

950

1950

2200

2400

5300-5301 (Xline=0.22)

800

900

950

1900

2200

2600

5600-5603 (Xline=0.22)

900

1050

1200

1500

1750

2000

5600-5601 (Xline=0.34)

800

900

950

1200

1500

1800

HVDC lines (Xline=0.01)

0

0

0

1000

1200

1500

5600-6000 (Xline=0.2)

1350

1500

1650

2100

2500

2900

5603-5610 (Xline=0.01)

0

0

0

2500

3000

3500

3000-3020 (Xline=0.01)

0

0

0

1500

1800

2100

7000-7010 (Xline=0.01)

0

0

0

2500

3000

3500

5301-5305 (Xline=0.12)

1250

1500

1700

2000

2200

2500

3115-3245 (Xline=0.5)

1100

1300

1400

1300

1800

2000

- Bus 3115 (Porjus): 2 generators

- Bus 3249 (Grundfors): 1 generator

- Bus 3300 (Oskarshamn): 3 generators

- Bus 5100 (Tretten): 1 generator

- Bus 5300 (Sima): 4 generators

- Bus 5500 (Oslo2): 1 generator

- Bus 5600 (Kristiansand): 2 generators

- Bus 6000 (Kvilldal): 3 generators

- Bus 6700 (Rossaga): 2 generators

Line Buses

Old R

Old X

Old B

New R

New X

New B

3100-3115

0.03

0.4

0.11

0.015

0.2

0.2

3100-3249

0.03

0.43

0.16

0.015

0.215

0.2

Trafo Buses

Old

Rate A

Old

Rate B

Old

Rate C

New

Rate A

New

Rate B

New

Rate C

3244-3245

500

500

0

2000

3000

4000

3249-3701

300

350

0

2000

3000

4000

3359-3360

1000

9000

9000

2000

3000

4000

5100-5101

1000

9000

9000

2000

3000

4000

5300-5301

2000

9000

9000

4000

4500

5000

5400-5401

1000

9000

9000

2000

3000

4000

5400-5402

1000

9000

9000

2200

3000

4000

5500-5501

1000

9000

9000

2000

3000

4000

5601-6001

1000

9000

9000

2000

3000

4000

5602-5603

1000

9000

9000

2000

3000

4000

6000-6001

1000

9000

9000

2200

3000

4000

6700-6701

1000

9000

9000

2000

3000

4000

Extends from Modelica.Icons.Example (Icon for runnable examples).