Generation groups for the examples that illustrate the use of typical data sets
| Name | Description |
|---|---|
| Generation Group for example that uses the IEEE421.5-based data set | |
| Generation Group for the example that uses the Anderson-based data set |
OpenIPSL.Data.PowerPlant.GenerationGroup.Generator1Generation Group for example that uses the IEEE421.5-based data set
Generation group for the example that uses the IEEE421.5-based data set.
The steps for the correct use of the data sets are indicated below:
OpenIPSL.Data.PowerPlant.GUDynamics
record to the diagram layer of your generation group model.GUnitDynamics parameter of the GUDynamics record.gUDynamics.guDynamics.machine.H.
To do this, you can either type the value or recreate the whole path,
by first clicking the Insert Component Reference option
and then navigating the references accordingly.Extends from OpenIPSL.Electrical.Essentials.pfComponent (Partial model containing all the parameters for entering power flow data).
| Name | Description |
|---|---|
| replaceable record GUnitDynamics | |
| Power flow data | |
| S_b | System base power [V.A] |
| V_b | Base voltage of the bus [V] |
| fn | System frequency [Hz] |
| P_0 | Initial active power [W] |
| Q_0 | Initial reactive power [var] |
| v_0 | Initial voltage magnitude [1] |
| angle_0 | Initial voltage angle [rad] |
| displayPF | Display power flow: |
| Parameter mask | |
| enableS_b | Enable S_b in parameter list |
| enableV_b | Enable V_b in parameter list |
| enablefn | Enable fn in parameter list |
| enableP_0 | Enable P_0 in parameter list |
| enableQ_0 | Enable Q_0 in parameter list |
| enablev_0 | Enable v_0 in parameter list |
| enableangle_0 | Enable angle_0 in parameter list |
| enabledisplayPF | Enable displayPF in parameter list |
| Name | Description |
|---|---|
| pwPin | |
| replaceable record GUnitDynamics |
OpenIPSL.Data.PowerPlant.GenerationGroup.Generator2Generation Group for the example that uses the Anderson-based data set
Generation Group for the example that uses the Anderson-based data set.
The steps for the correct use of the data sets are indicated below:
OpenIPSL.Data.PowerPlant.GUDynamics
record to the diagram layer of your generation group model.GUnitDynamics parameter of the GUDynamics record.gUDynamics.guDynamics.machine.H.
To do this, you can either type the value or recreate the whole path,
by first clicking the Insert Component Reference option and
then navigating the references accordingly.Extends from OpenIPSL.Electrical.Essentials.pfComponent (Partial model containing all the parameters for entering power flow data).
| Name | Description |
|---|---|
| replaceable record GUnitDynamics | |
| Power flow data | |
| S_b | System base power [V.A] |
| V_b | Base voltage of the bus [V] |
| fn | System frequency [Hz] |
| P_0 | Initial active power [W] |
| Q_0 | Initial reactive power [var] |
| v_0 | Initial voltage magnitude [1] |
| angle_0 | Initial voltage angle [rad] |
| displayPF | Display power flow: |
| Parameter mask | |
| enableS_b | Enable S_b in parameter list |
| enableV_b | Enable V_b in parameter list |
| enablefn | Enable fn in parameter list |
| enableP_0 | Enable P_0 in parameter list |
| enableQ_0 | Enable Q_0 in parameter list |
| enablev_0 | Enable v_0 in parameter list |
| enableangle_0 | Enable angle_0 in parameter list |
| enabledisplayPF | Enable displayPF in parameter list |
| Name | Description |
|---|---|