OpenIPSL.Data.PowerPlant.GenerationGroup

Generation groups for the examples that illustrate the use of typical data sets

Package Content

Name Description
OpenIPSL.Data.PowerPlant.GenerationGroup.Generator1 Generator1 Generation Group for example that uses the IEEE421.5-based data set
OpenIPSL.Data.PowerPlant.GenerationGroup.Generator2 Generator2 Generation Group for the example that uses the Anderson-based data set

OpenIPSL.Data.PowerPlant.GenerationGroup.Generator1 OpenIPSL.Data.PowerPlant.GenerationGroup.Generator1

Generation Group for example that uses the IEEE421.5-based data set

Information

Generation group for the example that uses the IEEE421.5-based data set.

Instructions

The steps for the correct use of the data sets are indicated below:

  1. Drag and Drop an instance of a OpenIPSL.Data.PowerPlant.GUDynamics record to the diagram layer of your generation group model.
  2. Propagate the GUnitDynamics parameter of the GUDynamics record.
  3. Go to the upper-level model that contains an instance of this generation group (e.g., IEEE421 example model). Complete the local instructions and come back to continue with step 4.
  4. Insert component references inside the parameter fields of the Synchronous Machine, Excitation System and Power System Stabilizer blocks. For example, to specify the inertia constant of the GENSAE synchronous machine (i.e., H), you must fill its field with this expression: gUDynamics.guDynamics.machine.H. To do this, you can either type the value or recreate the whole path, by first clicking the Insert Component Reference option and then navigating the references accordingly.

Extends from OpenIPSL.Electrical.Essentials.pfComponent (Partial model containing all the parameters for entering power flow data).

Parameters

NameDescription
replaceable record GUnitDynamics 
Power flow data
S_bSystem base power [V.A]
V_bBase voltage of the bus [V]
fnSystem frequency [Hz]
P_0Initial active power [W]
Q_0Initial reactive power [var]
v_0Initial voltage magnitude [1]
angle_0Initial voltage angle [rad]
displayPFDisplay power flow:
Parameter mask
enableS_bEnable S_b in parameter list
enableV_bEnable V_b in parameter list
enablefnEnable fn in parameter list
enableP_0Enable P_0 in parameter list
enableQ_0Enable Q_0 in parameter list
enablev_0Enable v_0 in parameter list
enableangle_0Enable angle_0 in parameter list
enabledisplayPFEnable displayPF in parameter list

Connectors

NameDescription
pwPin 
replaceable record GUnitDynamics 

OpenIPSL.Data.PowerPlant.GenerationGroup.Generator2 OpenIPSL.Data.PowerPlant.GenerationGroup.Generator2

Generation Group for the example that uses the Anderson-based data set

Information

Generation Group for the example that uses the Anderson-based data set.

Instructions

The steps for the correct use of the data sets are indicated below:

  1. Drag and Drop an instance of a OpenIPSL.Data.PowerPlant.GUDynamics record to the diagram layer of your generation group model.
  2. Propagate the GUnitDynamics parameter of the GUDynamics record.
  3. Go to the upper-level model that contains an instance of this generation group (e.g., Anderson example model). Complete the local instructions and come back to continue with step 4.
  4. Insert component references inside the parameter fields of the Synchronous Machine, Excitation System, Power System Stabilizer and Turbine/Governor blocks. For example, to specify the inertia constant of the GENROE synchronous machine (i.e., H), you must fill its field with this expression: gUDynamics.guDynamics.machine.H. To do this, you can either type the value or recreate the whole path, by first clicking the Insert Component Reference option and then navigating the references accordingly.

Extends from OpenIPSL.Electrical.Essentials.pfComponent (Partial model containing all the parameters for entering power flow data).

Parameters

NameDescription
replaceable record GUnitDynamics 
Power flow data
S_bSystem base power [V.A]
V_bBase voltage of the bus [V]
fnSystem frequency [Hz]
P_0Initial active power [W]
Q_0Initial reactive power [var]
v_0Initial voltage magnitude [1]
angle_0Initial voltage angle [rad]
displayPFDisplay power flow:
Parameter mask
enableS_bEnable S_b in parameter list
enableV_bEnable V_b in parameter list
enablefnEnable fn in parameter list
enableP_0Enable P_0 in parameter list
enableQ_0Enable Q_0 in parameter list
enablev_0Enable v_0 in parameter list
enableangle_0Enable angle_0 in parameter list
enabledisplayPFEnable displayPF in parameter list

Connectors

NameDescription
pwPin 
replaceable record GUnitDynamics 