OpenIPSL.Examples.DAEMode.N44_Base_Case_Systems

Test systems related to the N44 Base Case

Information

This package contains variants of Nordic 44 test system for testing performance of numerical solvers.

Extends from Modelica.Icons.ExamplesPackage (Icon for packages containing runnable examples).

Package Content

Name Description
OpenIPSL.Examples.DAEMode.N44_Base_Case_Systems.Nordic44_Base_Case_StateEvents Nordic44_Base_Case_StateEvents Modified version of the original Nordic 44 model, base class for Bus 5603 bus fault experiment
OpenIPSL.Examples.DAEMode.N44_Base_Case_Systems.Nordic44_Base_Case_StateEvents2 Nordic44_Base_Case_StateEvents2 Modified version of the original Nordic 44 model, used to simulate with DAE mode
OpenIPSL.Examples.DAEMode.N44_Base_Case_Systems.Nordic44_Base_Case_StateEvents3 Nordic44_Base_Case_StateEvents3 Bus 5603 bus fault experiments. The start values were given by simulating Nordic44_Base_Case_StateEvents2 from t = 0s to t = 60s. These start values have been stored in this model
OpenIPSL.Examples.DAEMode.N44_Base_Case_Systems.Generators Generators Group of generator models for N44 system simulations with events

OpenIPSL.Examples.DAEMode.N44_Base_Case_Systems.Nordic44_Base_Case_StateEvents OpenIPSL.Examples.DAEMode.N44_Base_Case_Systems.Nordic44_Base_Case_StateEvents

Modified version of the original Nordic 44 model, base class for Bus 5603 bus fault experiment

Information

Simulation of the Nordic 44 test system, in its base case scenario, with a fault occurring at bus , triggering several events. Try simulating the system with an fixed time-step solver, without a DAE mode, and with a time-step of 10ms.

Simulate the system for 5 seconds. Variables of interest are:

Compare with the results obtained in Nordic44_Base_Case_Bus_StateEvents2. Note that this test system takes a lot of time to simulate.

Extends from Modelica.Icons.Example (Icon for runnable examples).

OpenIPSL.Examples.DAEMode.N44_Base_Case_Systems.Nordic44_Base_Case_StateEvents2 OpenIPSL.Examples.DAEMode.N44_Base_Case_Systems.Nordic44_Base_Case_StateEvents2

Modified version of the original Nordic 44 model, used to simulate with DAE mode

Information

Simulation of the Nordic 44 test system, in its base case scenario, with a fault occurring at bus , triggering several events. Try simulating the system in DAE mode when in Dymola.

Simulate the system for 5 seconds. Variables of interest are:

Simulate Compare with the results obtained in Nordic44_Base_Case_Bus_StateEvents. Note that it takes significantly less time to simulate this system.

Extends from Modelica.Icons.Example (Icon for runnable examples).

OpenIPSL.Examples.DAEMode.N44_Base_Case_Systems.Nordic44_Base_Case_StateEvents3 OpenIPSL.Examples.DAEMode.N44_Base_Case_Systems.Nordic44_Base_Case_StateEvents3

Bus 5603 bus fault experiments. The start values were given by simulating Nordic44_Base_Case_StateEvents2 from t = 0s to t = 60s. These start values have been stored in this model

Information

Extends from OpenIPSL.Examples.DAEMode.N44_Base_Case_Systems.Nordic44_Base_Case_StateEvents (Modified version of the original Nordic 44 model, base class for Bus 5603 bus fault experiment).

Parameters

NameDescription
bus_7000 
G1_bus7100 
G2_bus7100 
G3_bus7100 
bus_7100 
bus_3115 
G1_bus3115 
G2_bus3115 
G3_bus3115 
line_3000_3115 
line_3100_3115 
line_3115_3249 
line_3115_3245 
bus_3000 
line_3000_3300_1 
line_3000_3245_1 
bus_3300 
bus_3200 
line_3100_3200_3 
line_3100_3200_2 
line_3100_3200_1 
bus_3100 
line_3300_8500_1 
bus_8500 
line_3359_8500_2 
line_3359_8500_1 
bus_3359 
line_3100_3249 
G1_bus3249 
G2_bus3249 
G3_bus3249 
G4_bus3249 
G5_bus3249 
G6_bus3249 
G7_bus3249 
bus_3701 
G1_bus3245 
bus_3244 
bus_6700 
G1_bus6700 
G2_bus6700 
bus_6500 
G1_bus6500 
G2_bus6500 
G3_bus6500 
G4_bus6500 
bus_5100 
G1_bus5100 
bus_5101 
line_5101_5103 
line_5101_5102 
line_5101_5501 
bus_5103 
line_5103_5304_2 
line_5103_5304_1 
line_5102_5103 
bus_5304 
line_5102_6001 
bus_5305 
line_5301_5304 
bus_5301 
line_5301_6001 
bus_5300 
G1_bus5300 
G2_bus5300 
bus_6100 
G1_bus6100 
G2_bus6100 
G4_bus6100 
G5_bus6100 
G3_bus6100 
line_6000_6100 
bus_6000 
G1_bus6000 
line_5400_6000 
bus_6001 
bus_5601 
bus_5600 
line_5600_5603 
G1_bus5600 
G2_bus5600 
bus_5603 
bus_5500 
line_5500_5603 
G1_bus5500 
bus_5401 
bus_5501 
bus_5400 
line_5401_6001 
G1_bus5400 
G2_bus5400 
G4_add_bus3115 
G5_add_bus3115 
G8_add_bus3249 
G2_add_bus5100 
G3_add_bus5300 
G4_add_bus5300 
G5_add_bus5300 
G6_add_bus5300 
G2_add_bus5500 
G3_add_bus5600 
G4_add_bus5600 
G2_add_bus6000 
G3_add_bus6000 
G4_add_bus6000 
G4_add_bus6700 
G3_add_bus6700 
genEventTest 
Automatically generated Thu Feb 26 06:55:59 2026.