OpenIPSL.Electrical.Machines.PSAT

Machine models from PSAT

Information

Extends from Modelica.Icons.Package (Icon for standard packages).

Package Content

Name Description
OpenIPSL.Electrical.Machines.PSAT.Order2 Order2 Second Order Synchronous Machine with Inputs and Outputs
OpenIPSL.Electrical.Machines.PSAT.Order3 Order3 Third Order Synchronous Machine with Inputs and Outputs
OpenIPSL.Electrical.Machines.PSAT.Order4 Order4 Fourth Order Synchronous Machine with Inputs and Outputs
OpenIPSL.Electrical.Machines.PSAT.Order5_Type1 Order5_Type1 5th order machine model, type 1
OpenIPSL.Electrical.Machines.PSAT.Order5_Type2 Order5_Type2 5th order machine model, type 2
OpenIPSL.Electrical.Machines.PSAT.Order6 Order6 6th order machine model
OpenIPSL.Electrical.Machines.PSAT.MotorTypeI MotorTypeI Induction Machine - Order I
OpenIPSL.Electrical.Machines.PSAT.MotorTypeIII MotorTypeIII Induction Machine - Order III
OpenIPSL.Electrical.Machines.PSAT.MotorTypeV MotorTypeV Induction Machine - Order V
OpenIPSL.Electrical.Machines.PSAT.BaseClasses BaseClasses Base classes for PSAT machines

OpenIPSL.Electrical.Machines.PSAT.Order2 OpenIPSL.Electrical.Machines.PSAT.Order2

Second Order Synchronous Machine with Inputs and Outputs

Information

Extends from BaseClasses.baseMachine (Base machine for PSAT models).

Parameters

NameDescription
Power flow data
S_bSystem base power [VA]
V_bBase voltage of the bus [V]
fnSystem frequency [Hz]
P_0Initial active power [W]
Q_0Initial reactive power [var]
v_0Initial voltage magnitude [1]
angle_0Initial voltage angle [rad]
displayPFDisplay power flow:
Machine parameters
SnPower rating [VA]
VnVoltage rating [V]
raArmature resistance [1]
x1dd-axis transient reactance [1]
MMechanical starting time, 2H [Ws/VA] [s]
DDamping coefficient
Initialization
wRotor speed [pu]

Connectors

NameDescription
p 
deltaRotor angle [rad]
vGenerator terminal voltage [pu]
PActive power [pu]
QReactive power [pu]
vf0Initial field voltage [pu]
pm0Initial mechanical power [pu]
pmMechanical power [pu]
Initialization
wRotor speed [pu]

OpenIPSL.Electrical.Machines.PSAT.Order3 OpenIPSL.Electrical.Machines.PSAT.Order3

Third Order Synchronous Machine with Inputs and Outputs

Information

Extends from BaseClasses.baseMachine (Base machine for PSAT models).

Parameters

NameDescription
Power flow data
S_bSystem base power [VA]
V_bBase voltage of the bus [V]
fnSystem frequency [Hz]
P_0Initial active power [W]
Q_0Initial reactive power [var]
v_0Initial voltage magnitude [1]
angle_0Initial voltage angle [rad]
displayPFDisplay power flow:
Machine parameters
SnPower rating [VA]
VnVoltage rating [V]
raArmature resistance [1]
x1dd-axis transient reactance [1]
MMechanical starting time, 2H [Ws/VA] [s]
DDamping coefficient
xdd-axis synchronous reactance [1]
T1d0d-axis open circuit transient time constant [s]
xqq-axis synchronous reactance [1]
Initialization
wRotor speed [pu]

Connectors

NameDescription
p 
deltaRotor angle [rad]
vGenerator terminal voltage [pu]
PActive power [pu]
QReactive power [pu]
vf0Initial field voltage [pu]
pm0Initial mechanical power [pu]
pmMechanical power [pu]
Initialization
wRotor speed [pu]

OpenIPSL.Electrical.Machines.PSAT.Order4 OpenIPSL.Electrical.Machines.PSAT.Order4

Fourth Order Synchronous Machine with Inputs and Outputs

Information

Extends from BaseClasses.baseMachine (Base machine for PSAT models).

Parameters

NameDescription
Power flow data
S_bSystem base power [VA]
V_bBase voltage of the bus [V]
fnSystem frequency [Hz]
P_0Initial active power [W]
Q_0Initial reactive power [var]
v_0Initial voltage magnitude [1]
angle_0Initial voltage angle [rad]
displayPFDisplay power flow:
Machine parameters
SnPower rating [VA]
VnVoltage rating [V]
raArmature resistance [1]
x1dd-axis transient reactance [1]
MMechanical starting time, 2H [Ws/VA] [s]
DDamping coefficient
xdd-axis synchronous reactance [1]
xqq-axis synchronous reactance [1]
x1qq-axis transient reactance [1]
T1d0d-axis open circuit transient time constant [s]
T1q0q-axis open circuit transient time constant [s]
Initialization
wRotor speed [pu]

Connectors

NameDescription
p 
deltaRotor angle [rad]
vGenerator terminal voltage [pu]
PActive power [pu]
QReactive power [pu]
vf0Initial field voltage [pu]
pm0Initial mechanical power [pu]
pmMechanical power [pu]
Initialization
wRotor speed [pu]

OpenIPSL.Electrical.Machines.PSAT.Order5_Type1 OpenIPSL.Electrical.Machines.PSAT.Order5_Type1

5th order machine model, type 1

Information

Extends from BaseClasses.baseMachine (Base machine for PSAT models).

Parameters

NameDescription
Power flow data
S_bSystem base power [VA]
V_bBase voltage of the bus [V]
fnSystem frequency [Hz]
P_0Initial active power [W]
Q_0Initial reactive power [var]
v_0Initial voltage magnitude [1]
angle_0Initial voltage angle [rad]
displayPFDisplay power flow:
Machine parameters
SnPower rating [VA]
VnVoltage rating [V]
raArmature resistance [1]
x1dd-axis transient reactance [1]
MMechanical starting time, 2H [Ws/VA] [s]
DDamping coefficient
xdd-axis synchronous reactance [1]
xqq-axis synchronous reactance [1]
x1qq-axis transient reactance [1]
T1d0d-axis open circuit transient time constant [s]
T1q0q-axis open circuit transient time constant [s]
T2q0q-axis open circuit sub-transient time constant [s]
Initialization
wRotor speed [pu]

Connectors

NameDescription
p 
deltaRotor angle [rad]
vGenerator terminal voltage [pu]
PActive power [pu]
QReactive power [pu]
vf0Initial field voltage [pu]
pm0Initial mechanical power [pu]
pmMechanical power [pu]
Initialization
wRotor speed [pu]

OpenIPSL.Electrical.Machines.PSAT.Order5_Type2 OpenIPSL.Electrical.Machines.PSAT.Order5_Type2

5th order machine model, type 2

Information

Extends from BaseClasses.baseMachine (Base machine for PSAT models).

Parameters

NameDescription
Power flow data
S_bSystem base power [VA]
V_bBase voltage of the bus [V]
fnSystem frequency [Hz]
P_0Initial active power [W]
Q_0Initial reactive power [var]
v_0Initial voltage magnitude [1]
angle_0Initial voltage angle [rad]
displayPFDisplay power flow:
Machine parameters
SnPower rating [VA]
VnVoltage rating [V]
raArmature resistance [1]
x1dd-axis transient reactance [1]
MMechanical starting time, 2H [Ws/VA] [s]
DDamping coefficient
xdd-axis synchronous reactance [1]
xqq-axis synchronous reactance [1]
x2dd-axis sub-transient reactance [1]
x2qq-axis sub-transient reactance [1]
T1d0d-axis open circuit transient time constant [s]
T2d0d-axis open circuit sub-transient time constant [s]
T2q0q-axis open circuit sub-transient time constant [s]
Taad-axis additional leakage time constant [s]
Initialization
wRotor speed [pu]

Connectors

NameDescription
p 
deltaRotor angle [rad]
vGenerator terminal voltage [pu]
PActive power [pu]
QReactive power [pu]
vf0Initial field voltage [pu]
pm0Initial mechanical power [pu]
pmMechanical power [pu]
Initialization
wRotor speed [pu]

OpenIPSL.Electrical.Machines.PSAT.Order6 OpenIPSL.Electrical.Machines.PSAT.Order6

6th order machine model

Information

Extends from BaseClasses.baseMachine (Base machine for PSAT models).

Parameters

NameDescription
Power flow data
S_bSystem base power [VA]
V_bBase voltage of the bus [V]
fnSystem frequency [Hz]
P_0Initial active power [W]
Q_0Initial reactive power [var]
v_0Initial voltage magnitude [1]
angle_0Initial voltage angle [rad]
displayPFDisplay power flow:
Machine parameters
SnPower rating [VA]
VnVoltage rating [V]
raArmature resistance [1]
x1dd-axis transient reactance [1]
MMechanical starting time, 2H [Ws/VA] [s]
DDamping coefficient
xdd-axis synchronous reactance [1]
xqq-axis synchronous reactance [1]
x1qq-axis transient reactance [1]
x2dd-axis sub-transient reactance [1]
x2qq-axis sub-transient reactance [1]
T1d0d-axis open circuit transient time constant [s]
T1q0q-axis open circuit transient time constant [s]
T2d0d-axis open circuit sub-transient time constant [s]
T2q0q-axis open circuit sub-transient time constant [s]
Taad-axis additional leakage time constant [s]
Initialization
wRotor speed [pu]

Connectors

NameDescription
p 
deltaRotor angle [rad]
vGenerator terminal voltage [pu]
PActive power [pu]
QReactive power [pu]
vf0Initial field voltage [pu]
pm0Initial mechanical power [pu]
pmMechanical power [pu]
Initialization
wRotor speed [pu]

OpenIPSL.Electrical.Machines.PSAT.MotorTypeI OpenIPSL.Electrical.Machines.PSAT.MotorTypeI

Induction Machine - Order I

Information

Extends from OpenIPSL.Electrical.Essentials.pfComponent (Partial model containing all the parameters for entering power flow data).

Parameters

NameDescription
Power flow data
S_bSystem base power [VA]
V_bBase voltage of the bus [V]
fnSystem frequency [Hz]
P_0Initial active power [W]
Q_0Initial reactive power [var]
v_0Initial voltage magnitude [1]
angle_0Initial voltage angle [rad]
displayPFDisplay power flow:
Machine parameters
SupStart-up control
RsStator resistance [1]
XsStator reactance [1]
Rr11st cage rotor resistance [1]
Xr11st cage rotor reactance [1]
XmMagnetizing reactance [1]
HmInertia constant [Ws/VA] [s]
a1st coefficient of tau_m(w) [1]
b2nd coefficient of tau_m(w) [1]
c3rd coefficient of tau_m(w) [1]
tupStart up time [s]
Parameter mask
enableS_bEnable S_b in parameter list
enableV_bEnable V_b in parameter list
enablefnEnable fn in parameter list
enableP_0Enable P_0 in parameter list
enableQ_0Enable Q_0 in parameter list
enablev_0Enable v_0 in parameter list
enableangle_0Enable angle_0 in parameter list
enabledisplayPFEnable displayPF in parameter list

Connectors

NameDescription
p 

OpenIPSL.Electrical.Machines.PSAT.MotorTypeIII OpenIPSL.Electrical.Machines.PSAT.MotorTypeIII

Induction Machine - Order III

Information

Extends from OpenIPSL.Electrical.Essentials.pfComponent (Partial model containing all the parameters for entering power flow data).

Parameters

NameDescription
Power flow data
S_bSystem base power [VA]
V_bBase voltage of the bus [V]
fnSystem frequency [Hz]
P_0Initial active power [W]
Q_0Initial reactive power [var]
v_0Initial voltage magnitude [1]
angle_0Initial voltage angle [rad]
displayPFDisplay power flow:
Machine parameters
SupStart up control
RsStator resistance [1]
XsStator reactance [1]
Rr11st cage rotor resistance [1]
Xr11st cage rotor reactance [1]
XmMagnetizing reactance [1]
HmInertia constant [s]
a1st coefficient of tau_m(w) [1]
b2nd coefficient of tau_m(w) [1]
c3rd coefficient of tau_m(w) [1]
tupStart up time [s]
Parameter mask
enableS_bEnable S_b in parameter list
enableV_bEnable V_b in parameter list
enablefnEnable fn in parameter list
enableP_0Enable P_0 in parameter list
enableQ_0Enable Q_0 in parameter list
enablev_0Enable v_0 in parameter list
enableangle_0Enable angle_0 in parameter list
enabledisplayPFEnable displayPF in parameter list

Connectors

NameDescription
p 

OpenIPSL.Electrical.Machines.PSAT.MotorTypeV OpenIPSL.Electrical.Machines.PSAT.MotorTypeV

Induction Machine - Order V

Information

Extends from OpenIPSL.Electrical.Essentials.pfComponent (Partial model containing all the parameters for entering power flow data).

Parameters

NameDescription
Power flow data
S_bSystem base power [VA]
V_bBase voltage of the bus [V]
fnSystem frequency [Hz]
P_0Initial active power [W]
Q_0Initial reactive power [var]
v_0Initial voltage magnitude [1]
angle_0Initial voltage angle [rad]
displayPFDisplay power flow:
Machine parameters
SupStart up control
RsStator resistance [1]
XsStator reactance [1]
Rr11st cage rotor resistance [1]
Xr11st cage rotor reactance [1]
Rr22nd cage rotor resistance [1]
Xr22nd cage rotor reactance [1]
XmMagnetizing reactance [1]
HmInertia constant [s]
a1st coefficient of tau_m(w) [1]
b2nd coefficient of tau_m(w) [1]
c3rd coefficient of tau_m(w) [1]
tupStart up time [s]
Parameter mask
enableS_bEnable S_b in parameter list
enableV_bEnable V_b in parameter list
enablefnEnable fn in parameter list
enableP_0Enable P_0 in parameter list
enableQ_0Enable Q_0 in parameter list
enablev_0Enable v_0 in parameter list
enableangle_0Enable angle_0 in parameter list
enabledisplayPFEnable displayPF in parameter list

Connectors

NameDescription
p 
Automatically generated Thu Oct 6 17:41:44 2022.