Models for the generation units used in the test systems
This package contains one generation unit composed by the standard models that are available in OpenIPSL and one generation unit that has additional components representing control systems that are used to resynchronize the generation unit to the power system.
Name | Description |
---|---|
G1 | Generation unit connected to bus BG1 |
G2 | Generation unit connected to bus B5 |
Generation unit connected to bus BG1
24kV/100MVA generation unit connected to bus BG1, and composed of the following component models:
Extends from OpenIPSL.Electrical.Essentials.pfComponent (Partial model containing all the parameters for entering power flow data).
Name | Description |
---|---|
Power flow data | |
S_b | System base power [VA] |
V_b | Base voltage of the bus [V] |
fn | System frequency [Hz] |
P_0 | Initial active power [W] |
Q_0 | Initial reactive power [var] |
v_0 | Initial voltage magnitude [1] |
angle_0 | Initial voltage angle [rad] |
displayPF | Display power flow: |
Parameter mask | |
enableS_b | Enable S_b in parameter list |
enableV_b | Enable V_b in parameter list |
enablefn | Enable fn in parameter list |
enableP_0 | Enable P_0 in parameter list |
enableQ_0 | Enable Q_0 in parameter list |
enablev_0 | Enable v_0 in parameter list |
enableangle_0 | Enable angle_0 in parameter list |
enabledisplayPF | Enable displayPF in parameter list |
Name | Description |
---|---|
conn |
Generation unit connected to bus B5
24kV/100MVA generation unit connected to bus BG1, and composed of the following component models:
This generation unit is supposed to be disconnected in all experiments and, then, to be resynchronized to the whole system.
Extends from OpenIPSL.Electrical.Essentials.pfComponent (Partial model containing all the parameters for entering power flow data).
Name | Description |
---|---|
Power flow data | |
S_b | System base power [VA] |
V_b | Base voltage of the bus [V] |
fn | System frequency [Hz] |
P_0 | Initial active power [W] |
Q_0 | Initial reactive power [var] |
v_0 | Initial voltage magnitude [1] |
angle_0 | Initial voltage angle [rad] |
displayPF | Display power flow: |
Parameter mask | |
enableS_b | Enable S_b in parameter list |
enableV_b | Enable V_b in parameter list |
enablefn | Enable fn in parameter list |
enableP_0 | Enable P_0 in parameter list |
enableQ_0 | Enable Q_0 in parameter list |
enablev_0 | Enable v_0 in parameter list |
enableangle_0 | Enable angle_0 in parameter list |
enabledisplayPF | Enable displayPF in parameter list |
Name | Description |
---|---|
conn | |
V_IB | |
V_DN | |
fi_IB | |
fi_DN | |
TRIGGER |